null

CyberPower PDU30SWHVT19ATNET Switched ATS PDU 200-240V 30A 2U 19-Outlets (2) L6-30P PDU30SWHVT19ATNET

No reviews yet Write a Review
SKU:
PDU30SWHVT19ATNET
CAD $1,200.99
Condition:
New
Shipping:
Calculated at Checkout

Description

The CyberPower PDU30SWHVT19ATNET, a 19-outlet (rear), 2U rackmount switched automatic transfer switch (ATS) power distribution unit (PDU), provides 200-240V 30A output. It distributes unfiltered electrical pass-through to to 19 receptacles--16 IEC-320 C13, 2 IEC-320 C19, and 1 NEMA L6-30R receptacles-from redundant NEMA L6-30P plugs. Dual power cords can be plugged into separate power sources to provide redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable.

The PDU30SWHVT19ATNET includes a SNMP/HTTP card (RMCARD203). With the SNMP card and an IP address on the network interface, users have real-time monitoring and outlet control of the PDU. The switched outlet receptacles can be managed individually or collectively. The LCD panel provides local monitoring of the PDU and on/off control for the outlets. It can also be used to measure the electrical current (displayed in amperes) used by connected equipment. The LCD panel also shows input and output voltages, active power consumption levels (displayed in kilowatts), and hardware and firmware versions.

Designed for datacenters and other demanding electrical applications, the PDU30SWHVT19ATNET has rugged, industrial-grade metal housing, a 10-foot AC power cord, and a cord retention tray. It can be mounted horizontally and is UL and CSA certified by ETL, and Class A FCC-certified. A three-year warranty covers the PDU and connected equipment for as long as you own the product.

Power Distribution
Delivers AC power to servers, equipment, and connected devices via a power distribution unit.

Outlet Switching
Output receptacles can be turned on, turned off, or recycled on demand or at programmed times to address a number of needs, including remote rebooting of locked equipment, load shedding, power sequencing, and locking out unauthorized loads.

Automatic Transfer Switch
Dual power cords (A & B) provide redundant power sources to devices with single power supplies and can be plugged into separate compatible sources to ensure continuous access. Users select the preferred source as the primary input. CyberPower Smart App Online and Sinewave series UPS are highly recommended for use as the power source.

LCD Panel
Provides real-time meter status for current (amperes), input and output voltages, power consumptions (kilowatts), and hardware/firmware versions.

Upgradeable Hardware & LCD Firmware
Are updatable to the latest versions by using the serial communication port and included cable.

Serial Communication Port & Cable
Used to update/upgrade the hardware and LCD firmware.

Environmental Sensor Option
Supports optional environment sensor (ENVIROSENSOR).

SNMP/HTTP Card
Included and installed, RMCARD203 provides outlet control, remote monitoring, reporting, and event notifications, via Email, SMS Text, or SNMP Trap. RMCARD203 firmware is upgradeable with FTP process.

Protocol Support
This Switched ATS PDU provides protocol support for PowerPanel Business Edition, HTTP, TCP/IP, UDP, DHCP, and SNMP including SNMPv3, and IPv4, IPv6, NTP, SMTP protocols.

Administrative Rights
Administrator and user rights can be established to provide IT personnel with access to the Management Console via a web browser to monitor and/or manage the PDU settings.
  • 200V - 240V 30A Switched ATS PDU with 16 IEC-320 C13 outlets, 2 IEC-320 C19 & 1 NEMA L6-30R outlets and dual NEMA L6-30P 30A high-voltage input connections
  • Switched Automatic Transfer Switching (ATS) PDU to provide a redundant input power option
  • Digital Display (Load, Voltage, and KW) for on-site monitoring of total PDU load
  • SNMP/HTTP Network Interface for real-time outlet control, monitoring and event logging of the Switched ATS PDU
  • Energy Star : No
  • Product Series : Switched ATS PDU
  • Phase : Single Phase
  • Input Voltage : 230 V AC
  • Management :
    • HTTP
    • TCP/IP
    • UDP
    • DHCP
    • SNMP
    • SNMPv3
    • IPv4
    • IPv6
    • NTP
    • SMTP
  • Rack Height : 2U
  • Output Voltage Range : 200 V AC - 240 V AC
  • Input Current : 30 A
  • PDU Type : Switched Auto Transfer Switch
  • Mount Type : Rack-mountable
  • Package Contents :
    • PDU30SWHVT19ATNET Switched ATS PDU 200-240V 30A 2U 19-Outlets (2) L6-30P
    • 2 x Mounting Brackets
    • 24 x M4x8 Bracket Mounting Screws
    • 6 x M5x12 Rack Mounting Screws
    • 6 x Washers
    • 2 x Cord Retention Trays
    • 4 x M3x4 Cord Retention Tray Mounting Screws
    • 30 x Cable Ties
    • RJ45/DB9 Serial Port Connection Cable
    • Jumper
    • User Manual
    • Registration Card
    • CD
    • 4 x IEC Socket Power Cord Stands
    • 29 x M3x4 Screws
    • 27 x Power Cord Retention Cable Clip
    • 27 x Cable Ties
  • Manufacturer Website Address : http://www.cyberpowersystems.com
  • Plug/Connector Detail : 2 x NEMA L6-30P
  • Input Voltage Range : 200 V AC - 240 V AC
  • Environmentally Friendly : Yes
  • Plug/Connector Type : NEMA L6-30P
  • Environmental Certification : RoHS
  • Manufacturer : CyberPower Systems, Inc
  • Product Type : PDU
  • Receptacle Type : NEMA L6-30R
  • Limited Warranty : 3 Year
  • Receptacle Detail : 1 x NEMA L6-30R
  • Product Model : PDU30SWHVT19ATNET
  • Country of Origin : China

Extra Information

Brand:
CyberPower
Environmentally Friendly:
Yes
Energy Star:
No
Rack Height:
2U
Environmental Certification:
RoHS
Limited Warranty:
3 Year
Package Contents:
PDU30SWHVT19ATNET Switched ATS PDU 200-240V 30A 2U 19-Outlets (2) L6-30P 2 x Mounting Brackets 24 x M4x8 Bracket Mounting Screws 6 x M5x12 Rack Mounting Screws 6 x Washers 2 x Cord Retention Trays
Product Model:
PDU30SWHVT19ATNET
Manufacturer:
CyberPower Systems, Inc
Product Type:
PDU
Input Voltage Range:
200 V AC - 240 V AC
PDU Type:
Switched Auto Transfer Switch
Management:
HTTP TCP/IP UDP DHCP SNMP SNMPv3 IPv4 IPv6 NTP SMTP
Output Voltage Range:
200 V AC - 240 V AC
Phase:
Single Phase
Mount Type:
Rack-mountable
Input Current:
30 A
Manufacturer Website Address:
http://www.cyberpowersystems.com
Input Voltage:
230 V AC
Country of Origin:
China
Plug/Connector Detail:
2 x NEMA L6-30P
Product Series:
Switched ATS PDU
Receptacle Type:
NEMA L6-30R
Receptacle Detail:
1 x NEMA L6-30R
Plug/Connector Type:
NEMA L6-30P

Warranty Information

Three Year Manufacturer Warranty